Call UsCall Us : 08045800824
Vacuum Circuit Breaker Gear
Vacuum Circuit Breaker Gear

Vacuum Circuit Breaker Gear

Vacuum Circuit Breaker Gear Specification

  • Power Supply
  • Electric
  • Usage
  • Industrial, Power Distribution
  • Power Source
  • Electric
  • Operating Temperature
  • -10C to +50C
  • Response Time
  • <50 ms
  • Features
  • Compact design, High life expectancy, Safe operation, Maintenance free
  • Charging Voltage
  • 110V/220V for spring charging motor
  • Interface
  • Control and protection terminals
  • IP Rating
  • IP4X
  • Display Type
  • Analog Indication
  • Input
  • AC High Voltage
  • Output
  • Isolated/Protected Load
  • Sensors Specification
  • Auxiliary Contact Sensors
  • Components
  • Vacuum Interrupter, Operating Mechanism, Spring, Contacts, Enclosure
  • Product Type
  • Vacuum Circuit Breaker Gear
  • Application
  • Medium Voltage Distribution
  • Rated Voltage
  • 11 kV
  • Supply Voltage
  • 11,000 V
  • Size
  • Standard Panel size
  • Dimension (L*W*H)
  • 1000 x 800 x 2200 mm
  • Function
  • Automatic circuit interruption under fault condition
  • Color
  • Grey
  • Weight
  • Approx. 120 kg
  • Current Rating
  • Up to 1250 Amps
  • Capacity
  • 630A / 800A / 1250A
  • Thickness
  • 3 mm (enclosure)
  • Frequency
  • 50 Hz
  • Insulation Level
  • 28 kV (1 min) Power Frequency withstand
  • Mounting Type
  • Floor Mounted
  • Closing/Opening Mechanism
  • Spring Charged Mechanism
  • Mechanical Endurance
  • 10,000 operations
  • Arcing Time
  • <3 cycles
  • Making Capacity
  • 63 kA peak
  • Interlocking
  • Mechanical & Electrical Interlock
  • Operating Mechanism Type
  • Manual / Motor operated
  • Ambient Humidity
  • Up to 95% RH (non-condensing)
  • Standards Complied
  • IS/IEC 62271-100
  • Control Circuit Voltage
  • 110-220V AC/DC
  • Short Circuit Breaking Capacity
  • Up to 25 kA
  • Auxiliary Supply Voltage
  • 110V / 220V AC/DC
  • Phase
  • Three Phase
 
 

About Vacuum Circuit Breaker Gear

Our Vacuum Circuit Breaker Gear is an optimal choice for your electrical circuit needs. With a robust construction and reliable voltage input and output ratings, this robust breaker guarantees consistent current flow while safeguarding your electrical setup against surges and overloads. Offering superior performance and durability, this product is an incredibly reliable choice.


Superior Performance Under Fault Conditions

The vacuum circuit breaker gear delivers automatic interruption during fault scenarios with a swift arcing time of less than 3 cycles and a rapid response time below 50 milliseconds. Designed for industrial power distribution, it isolates and protects loads efficiently, reducing downtime and ensuring operational safety in high-voltage networks.


Robust Construction for Demanding Environments

Housed within a 3 mm thick enclosure and rated IP4X, this breaker maintains performance in ambient humidity up to 95% RH (non-condensing) and temperatures from -10C to +50C. Its compact design and standard panel dimensions (1000 x 800 x 2200 mm) make it suitable for various installation requirements, providing flexibility and reliability wherever it is deployed.

FAQs of Vacuum Circuit Breaker Gear:


Q: How does the vacuum circuit breaker gear ensure safe operation during high fault conditions?

A: It employs a vacuum interrupter that enables automatic circuit interruption under fault conditions, with a short arcing time of less than 3 cycles and response time below 50 ms, minimizing risk and safeguarding connected equipment.

Q: What is the process for spring charging in this breaker and what voltage is required?

A: The gear features a spring charged closing/opening mechanism that can be operated manually or by a motor. The spring charging motor requires a charging voltage of either 110V or 220V AC/DC, ensuring readiness for operation.

Q: When is maintenance required for this circuit breaker, and is it considered maintenance free?

A: Designed for high mechanical endurance of up to 10,000 operations and built with robust components, this gear is categorized as maintenance free for normal operation, which significantly reduces routine upkeep and associated costs.

Q: Where is the ideal installation environment for the vacuum circuit breaker gear?

A: This breaker is suitable for industrial settings with medium voltage distribution, operating effectively in ambient humidity up to 95% RH and temperatures ranging from -10C to +50C. It is floor-mounted for stability and conforms to standard panel sizes, facilitating easy integration.

Q: What are the benefits of its compact design and standard enclosure size?

A: The compact design and standard dimensions (1000 x 800 x 2200 mm) allow for efficient use of space within substations and industrial facilities, while its IP4X enclosure enhances safety by protecting against dust and accidental contact.

Q: How does the control and protection system interface with auxiliary supply voltages?

A: The gear supports auxiliary supply voltages of 110V or 220V AC/DC, facilitating effective integration of control and protection terminals as well as auxiliary contact sensors, offering flexible monitoring and control options for operators.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Vacuum Circuit Breaker Parts Category

11 KV - 33 KV Cgl VCB Epoxy Spout

11 KV - 33 KV Cgl VCB Epoxy Spout

Product Type : Epoxy Spout

Components : Molded epoxy body, metal inserts (if included)

Size : Standard as per CGL VCB design

Frequency : 50 Hz

Thickness : 612 mm (approximate, varies by voltage rating)

11 KV - 33 KV VCB Epoxy Spout

11 KV - 33 KV VCB Epoxy Spout

Product Type : Epoxy Spout

Components : Epoxy Resin Moulded Body

Size : Standard VCB spout sizes; customized options available

Frequency : 50 Hz / 60 Hz

Thickness : 812 mm (average wall thickness)

Siemens VCB Spout Epoxy Housing

Siemens VCB Spout Epoxy Housing

Product Type : Epoxy Spout Housing

Components : Epoxy resin molded housing unit

Size : Standard Siemens VCB compatible

Frequency : 50Hz / 60Hz

Thickness : 6 mm nominal

VACCUM INTRAPTOR WL 34599M3+

VACCUM INTRAPTOR WL 34599M3+

Minimum Order Quantity : 1